all-sun 3 in 1 Digital Multimeter Voltmeter Ammeter Ohmmeter DC AC EMF Multimeter LCD Multi-function Automotive Tester EM5511

NOTE: The package content is not included battery.Due to china post new rules can’t send goods with battery.

This multimeter is 4000 count,3 3/4-digit digital multimeter.It can be used to measure DC and AC voltage, DC and AC current,resistance,capacitance,frequecy,diode, temperature, continuity,duty cycle and electromagnetic field radiation. It can be used as a test tool for environment and devices, it is a high-performance and versatile meter.

FEATURE

1)High-performance

2)3 3/4-backlight LCD display,max.reading of 3999

3)Data-hold mode

4)Auto polarity indication

5)Manual range and autorange mode

6)Auto/manual power-off

7)Relative mode

8)Overload protection

9)Low battery indication

Display:3 3/4-digit LCD,with a max,reading of 3999

Overrange Indication:”OL” shown on the LCD.

Negative Polarity Indiaction:”-” displayed automatically

Sampling Rate:2-3 times/sec

Operating Temperature:0-40 degree C,<75%RH

Storage Temperature:-30-60 degree C,<85%RH

Operating Altitude:0 to 2000 meters

Battery:9V,6F22 or equivalent

Dimensions:162x83x47mm

Weight:about 310g(including battery and the holster)

SPECIFICATION

Accuracy is specified for a period of one year after calibration and at 18 degree C to 28 degree C,with relative humidity <75%.Normally,accuracy specifications take the form of: ±([% of Reading]+[number of Least Significant Digits])

DC Voltage

Range

Resolution

Accuracy

400mV

0.1mV

±(1.0%+5)

4V

1mV

±(0.8%+3)

40V

10mV

400V

100mV

250V

1V

±(1.0%+5)

Input Impedance:the 400mV range:>1000MΩ

the other ranges:10MΩ

Max.Permitted Input:250V DC or AC

AC Voltage

Range

Resolution

Accuracy

4V

1mV

±(1.0%+5)

40V

10mV

400V

100mV

250V

1V

±(1.2%+5)

Input Impedance: 10MΩ

Max.Permitted Input:250V DC or AC

Frequency Range:40Hz ~400Hz

Response:Average,calibrated in rms of sine wave.

DC Current

Range

Resolution

Accuracy

400uA

0.1uA

±(1.2%+3)

4000 uA

1 uA

40mA

10 uA

400mA

100 uA

4A

1mA

±(1.8%+3)

10A

10mA

±(2.0%+5)

Overload Protection:

For”mA”jack inputs:Fuse,500Ma/250V,fast action,

For”10A”jack inputs:Fuse,10A/250V,fast action

Max.Input Current:10A(For inputs>5A:measurement duration<10secs,interval>15minutes)

Max.Voltage Drop:400Mv

AC Current

Range

Resolution

Accuracy

400uA

0.1uA

±(1.2%+3)

4000 uA

1 uA

40mA

10 uA

400mA

100 uA

4A

1mA

±(1.8%+3)

10A

10mA

±(2.0%+5)

Overload Protection:

For”mA degree C”jack inputs:Fuse,500Ma/250V,fast action,

For”10A”jack inputs:Fuse,10A/250V,fast action

Max.Input Current:10A(For inputs>5A:measurement duration<10secs,interval>15minutes)

Max.Voltage Drop:400Mv

Frequency Range:40Hz~400Hz

Response:Average,calibrated in rms of sine wave.

RESISTANCE

Range

Resolution

Accuracy

400Ω

0.1Ω

±(1.0%+5)

4kΩ

±(1.0%+3)

40 kΩ

10Ω

400 kΩ

100Ω

4MΩ

1kΩ

40MΩ

10kΩ

±(2.0%+5)

Overload Protection:250V DC/AC

Open Circuit Voltage:about 0.25V

FREQUENCY

Range

Resolution

Accuracy

10Hz

0.01Hz

±(1.0%+3)

100Hz

0.1Hz

±(0.8%+3)

1kHz

1 Hz

10kHz

10 Hz

100kHz

100 Hz

±(1.0%+3)

200kHz

1kHz

>200kHz

Not specified

Input voltage:1 Vrms~20 Vrms

Overload Protection:250VDC/AC

CAPACITANCE(use Relative mode)

Range

Resolution

Accuracy

4nF

0.001nF

±(4.0%+5)

40nF

0.01nF

400nF

0.1nF

4uF

1nF

40uF

10nF

100uF

100nF

±(8.0%+5)

Overload Protection:250V DC/AC

TEMPERATURE

Range

Resolution

Accuracy

-20 degree C~400 degree C

0.01 degree C

±1.5%±3 degree C

400 degree C~1000 degree C

1 degree C

±2.0%±3 degree C

Overload Protection:Fuse,500Ma/250V,fast action.

DUTY CYCLE

Range

Resolution

Accuracy

5%~95%

0.1%

1Hz~10kHz:±(2.0%+5)

>10kHz:not specified

Input Voltage:3Vp-p~10Vp-p

Overload Protection:250V DC/AC

ELECTROMAGNETIC RADIATION

Range

Resolution

Accuracy

400mG

0.1mG

1Hz~10kHz:±(2.0%+5)

4000mG

1mG

±(5%+3) at 50Hz/60Hz

Frequency Scope:40~400Hz(Single axis measurements only)

1 Tesla=1000Gauss; 1Gauss=1000 Milligauss

ACCESSORIES:

Test Lead; Temperature probe; Battery; Users Manual; Holster

Average Star Rating:
0 out of 5 (0 Ratings)
Name Rating Feedback
Shipping Company Shipping Cost Estimated Delivery Time
DHL 3 - 7 days
UPS Expedited 3 - 7 days
EMS 5 - 14 days
Post Air Mail Free Shipping 15 - 45 days
Return Policy If the product you receive is not as described or low quality, the seller promises that you may return it before order completion (when you click "Confirm Order Received" or exceed confirmation timeframe) and receive a full refund. The return shipping fee will be paid by you. Or, you can choose to keep the product and agree the refund amount directly with the seller.

N.B.: If the seller provides the "Longer Protection" service on this product, you may ask for refund up to 15 days after order completion.
Seller Service On-time DeliveryIf you do not receive your purchase within 60 days, you can ask for a full refund before order completion (when you click "Confirm Order Received" or exceed confirmation timeframe).

Customers Who Bought This Item Also Bought

Price:  US $80.40 / piece
Sale Price:  US $25.73 / piece
UP